Powerbridge SWCK Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour les appareils électriques Powerbridge SWCK. PowerBridge SWCK User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Shallow-Wall Connector Kit Model SWCK
Power Extension Cable Management
THIS PRODUCT IS NOT TO BE INSTALLED, DIRECT WIRED, OR BRANCHED TO THE BUILDING ELECTRICAL CIRCUIT/WIRING SYSTEM !
DO NOT MODIFY OR ALTER ANY PORTION OF THE COMPONENTS OF THE FACTORY ASSEMBLED APPLIANCE
Do not install this product near water, example, near a sink, tub, shower, swimming pool or laundry area.
Manufacturer is not liable for damages due to improper installation methods not followed herein.
This product does not have built-in electronic circuitry for surge protection or A/C filtering.
It is recommended that this product be connected to a quality surge-protector/power conditioner for equipment protection.
Disclaimer. HD-Products, Inc. the Manufacturer, it's agents, suppliers, and affiliates, shall not be liable for any damages, not limited to; misuse, acts of nature,
verbal and written expression and improper installation. Improper installation is determined such to include, not limited to, non-code compliant installation, product
modifications, alterations, adjustments, and substitutions of components or materials.
Limited 2-year Warranty from Manufactures Defects: The SWCK has a Limited Two Year product warranty against manufacturer's defects.
If you have any questions or experience any problems with this product, please contact HD-Products Customer Service.
Step 1 Location - Wall Cutout
Determine TV wall mount location.
Align between wall framing studs.
Use stud finder to determine in-wall obstructions between
framing both VERTICALLY and HORIZONTALLY.
Install horizontal or vertical
Align PowerIN with upper TV PowerOUT within same stud-bay
no more than 60” apart.
Install PowerOUT no more than 60” apart from the lower PowerIN,
*unless you install optional PowerConnector Extension part CKRE
Use supplied template sheet to mark area to cut out from drywall.
Use a level to maintain proper alignment.
Carefully use drywall saw to cut along outside of line.
Do not exceed more
than 60” apart*
PowerOUT
PowerIN
HD-Products, Inc., intent to make this manual accurate and complete. However, HD-Products, Inc., makes no claim that the information contained herein covers all details, conditions, or
variations. Nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change
without notice or obligation of any kind. HD-Products, Inc., makes no representation of warranty, expressed or implied, regarding the information contained herein.
HD-Products, Inc. PowerBridge Solution 3869 Norwood Dr. Littleton, CO 80125 USA
Customer Service: 303-683-2434 info@powerbridgesolution.com www.PowerBridgeSolution.com
Part No. 21114-1 2014 All Rights Reserved Patent Pending
|
Kit Includes:
Slim-line In-Wall Power Outlet and Power Inlet Wall Panels Pre-wired PowerConnectors.
1’ outlet connection / 6’ inlet connection. 6’ PowerConnect Cord Cutout template.
Only attempt installation within
2x2 or 2x4 wood/metal stud
framed wall. ½”drywall minimum
*Extend distance between
PowerIN and PowerIN
use optional part CKRE
PowerConnect Extension
!
!
In-Wall Power for Shallow Walls (2x2 framing)
PowerOUT Panel
If insulation exists, remove or push
completely away from the openings
to allow flush mounting properly.
LEVEL
!
Wall Cut-out Template:
Lay against wall, use a level on edge of pape
Use a pencil to trace around edge.
Use drywall saw or sharp utility knife cut on t
Tools for Installation
Not Included
Stud Finder
Flat-Blade
Drywall Saw
Level
CODE COMPLIANCY
SUPPORT
1)NEC Article 334.30
Unsupported NM Cable
2) NEC 2014 Article 400.7(A)(11)
Permitted use of cord / approved kit
using inlet to energize receptacle
Meets all US states and cities
adaptive to the National
Electrical Code (NEC)
allowing NM type building cable.
Specific locations not allowing
NM-type building cable:
~Cook County, IL ~NYC, NY
PowerOUT
or
PowerIN Panel
Do not exceed more
than 60” apart from
existing outlet or
surge-protection unit
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Location - Wall Cutout

Shallow-Wall Connector Kit Model SWCKPower Extension Cable Management THIS PRODUCT IS NOT TO BE INSTALLED, DIRECT WIRED, OR BRANCHED TO THE BUILDING

Page 2 - Plug it in

Step 2Wall InstallationA) Begin at the upper TV PowerOUT location. 1) Drop / wall-fish audio/video cables to the lower PowerIN location

Commentaires sur ces manuels

Pas de commentaire